Page 107 - Florida-Strut-Catalog-2021
P. 107

Continuous Concrete Inserts FS12158NS - 15⁄8" x 15⁄8" - 12 Gauge
A ZSi-Foster Company
Size
     W7250 to W7252
Concrete Insert
W5952
  New Item W7250
W7251
W7252
31⁄8"
     Part No.
  Size
  Anchor End Caps
  Wt. / CPCS
  Allowable Load Lbs. (kN)
   79mm
 4" (102mm)
6" (152mm)
8" (203mm)
W5952
110 (50 Kg)
140 (64 Kg)
170 (77 Kg)
800 (3.56 kN)
1000 (4.45 kN)
1200 (5.34 kN)
     Refer to page 96 for continuous concrete insert part number selection chart to build complete part number based on desired options .
W7253 to W7270
Continuous Inserts
When ordering specify finish. Available in plain, pre-galvanized, hot dip galvanized after fabrication, type 304 and 316 stainless steel .
New Item
W7253 *
W7254
W7255
W7256
W7257
W7257A
W7258
W7259
W7260
W7261
W7262
W7263
W7264
W7265
W7266
W7267
W7268
W7269
W7270
4"
102mm
102mm
  4"
 4"
102mm
 12" (305mm)
16" (406mm)
20" (508mm)
24" (610mm)
32" (813mm)
36" (914mm)
40" (1016mm)
4' (1.2m)
5' (1.5m)
6' (1.8m)
7' (2.1m)
8' (2.4m)
9' (2.7m)
10' (3m)
12'(3.6m)
14' (4.2m)
16' (4.8m)
18' (5.4m)
20' (6.1m)
W5952
240# (108.8 Kg)
300# (136 Kg) 360# (163.2 Kg) 430# (196 Kg) 560# (254 Kg) 620# (281.2 Kg) 680# (308.4 Kg) 810# (367.4 Kg) 1,000# (453.5 Kg) 1,200# (544.3 Kg) 1,380# (625.9 Kg) 1,570# (712.1 Kg) 1,770# (802.5 Kg) 1,910# (866.3 Kg) 2,340# (1061.4 Kg) 2,720# (1233.7 Kg) 3,100# (1406.1 Kg) 3,480# (1578.5 Kg) 3,870# (1755.4 Kg)
41mm
Waterproof Sealer Tape and Rigid Foam Filler shown exposed in place
FS12158NS
Rigid Foam Filler
2"
W5930 End Cap
1 3⁄8"
35mm
1 5⁄8"
41mm
51mm
1 5⁄8"
 Part No.
  Size
  End Cap
  Wt. / CPCS
  Allowable Load Lbs. (kN)
  1 5⁄8"
 3⁄4"
19mm
1 5⁄8"
41mm
Concentrated load on the end 2" (51mm) of W7252 thru W7270 should not exceed 1000# . Inserts must be surrounded by sufficient concrete to conform to design shear stress . Concrete insert should be nailed to form every 16" to 24" (406mm to 635mm)
                 W5930
2000 41mm (8.90 kN)
                   * W7253 utilizes tab channel (punched & anchor caps)
 Refer to page 105 for continuous concrete insert part number selection chart to build complete part number based on desired options .
Florida Strut Engineering Catalog
WARNING: These products can expose you to chemicals including lead, which is known to the State of California to cause cancer, and which is known to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
– 107 –