Page 109 - Florida-Strut-Catalog-2021
P. 109

Continuous Concrete Inserts FS12100NS - 15⁄8" x 1" - 12 Gauge
A ZSi-Foster Company
Size
     W7550 to W7552
Concrete Insert
W5958
  New Item W7550
W7551
W7552
23⁄8"
     Part No.
  Size
  Anchor End Caps
  Wt. / CPCS
  Allowable Load Lbs. (kN)
  4" (102mm)
6" (152mm)
8" (203mm)
W5958
74# (33.5 Kg)
99# (44.9 Kg)
124# (56.2 Kg)
500 (2.22 kN)
750 (3.34 kN)
1000 (4.45 kN)
60mm
      Refer to page 96 for continuous concrete insert part number selection chart to build complete part number based on desired options .
W7553 to W7570
12 Gauge, Continuous Concrete Inserts
When ordering specify finish. Available in plain, pre-galvanized, hot dip galvanized after fabrication, 304 and 316 stainless steel .
4"
102mm
102mm
  4"
 New Item
W7553 *
W7554
W7555
W7556
W7557
W7557A
W7558
W7559
W7560
W7561
W7562
W7563
W7564
W7565
W7566
W7567
W7568
W7569
W7570
4"
102mm
2"
 12" (305mm)
16" (406mm)
20" (508mm)
24" (610mm)
32" (813mm)
36" (914mm)
40" (1016mm)
4' (1.2m)
5' (1.5m)
6' (1.8m)
7' (2.1m)
8' (2.4m)
9' (2.7m)
10' (3m)
12'(3.6m)
14' (4.2m)
16' (4.8m)
18' (5.4m)
20' (6.1m)
W5958
163# (73.9 Kg)
213# (96.6 Kg) 263# (119.2 Kg) 313# (141.9 Kg) 414# (187.7 Kg) 464# (210.4 Kg) 510# (231.3 Kg) 615# (278.9 Kg) 766# (347.4 Kg) 916# (415.4 Kg) 1079# (489.4 Kg) 1218# (552.4 Kg) 1368# (620.5 Kg) 1519# (689 Kg) 1820# (825.5 Kg) 2122# (962.5 Kg) 2423# (1099 Kg) 2725# (1236 Kg) 3026# (1372.5 Kg)
1 5⁄8"
Rigid Foam Filler
FS12100NS
51mm
W5938 End Cap
1 3⁄8"
35mm
1"
25mm
25mm
41mm
1"
 Part No.
  Size
  End Cap Number
  Wt. / CPCS
  Allowable Load Lbs. (kN)
                    W5938
1500
(6.67 kN)
3⁄4"
19mm
1 5⁄8"
41mm
      Concentrated load on the end 2" (51mm)
of W7552 thru W7570 should not exceed
750# . Inserts must be surrounded by
sufficient concrete to conform to design
shear stress . Concrete insert should be
nailed to form every 16" to 24" (406mm to 635mm)
             * W7553 utilizes tab channel (punched & anchor caps)
 Refer to page 105 for continuous concrete insert part number selection chart to build complete part number based on desired options .
Florida Strut Engineering Catalog
– 109 –
 WARNING: These products can expose you to chemicals including lead, which is known to the State of California to cause cancer, and which is known to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.